Vacuum Sterilizer

This series pulse vacuum sterilizer is used for sterilizing medical liquids, surgical instruments and fabrics in medical and pharmaceutical institutions. Application: It can be widely used in department of stomatology and ophthalmology, operating room and other medical institutions

MODEL AVAILABLES:

  1. Pulse Vacuum Autoclave with built-in Steam Generator,Single Door ,Capacity 0.25m3
  2. Pulse Vacuum Autoclave with built-in Steam Generator,Double Door ,Capacity 0.25m3
  3. Pulse Vacuum Autoclave with built-in Steam Generator,Single Door,Capacity 0.36m3
  4. Pulse Vacuum Autoclave with built-in Steam Generator,Double Door ,Capacity 0.36m3
  5. Pulse Vacuum Autoclave with built-in Steam Generator,Single Door,Capacity 0.6m3
  6. Pulse Vacuum Autoclave with built-in Steam Generator,Double Door,Capacity 0.6m3
  7. Pulse Vacuum Autoclave,Single Door,Capacity 0.8m3 Pulse Vacuum Autoclave,Double Door,Capacity 0.8m3
  8. Pulse Vacuum Autoclave,Single Door,Capacity 1.2m3
  9. Pulse Vacuum Autoclave,Double Door,Capacity 1.2m3
  10. Pulse Vacuum Autoclave,Single Door,Capacity 1.5m3
  11. Pulse Vacuum Autoclave,Double Door,Capacity 1.5m3
  12. Pulse Vacuum Autoclave,Single Door,Capacity 2.0m3
  13. Pulse Vacuum Autoclave,Double Door,Capacity 2.0m3
  14. Pulse Vacuum Autoclave,Single Door,Capacity 2.5m3
  15. Pulse Vacuum Autoclave,Double Door,Capacity 2.5m3
  16. Steam Generator ( Use for Capacity 0.8- 1.5m3 Pulse Vacuum Autoclave)
  17. Steam Generator ( Use for Capacity 2.0- 2.5m3 Pulse Vacuum Autoclave)

Note:

  • Capacity 0.8- 2.5m3 Pulse Vacuum Autoclave need to connect to Boiler Steam or buy above Electric Steam Generator.
  • Air Compressor Air Compressor for All Model of Pulse Vacuum Autoclave

Description

FEATURES:

  1. Capacity: 1.2m³
  2. Inner Chamber Dimension (L*W*H): 1500*680*1180mm
  3. Outer Dimension (L*W*H): 1790*1450*1950mm
  4. Steam Pressure and the Consumption: 0.4-0.8Mpa 48KG
  5. Water Source Pressure and the Consumption: 0.15-0.3Mpa 55KG
  6. Power: 4KW
  7. Net Weight: 1800Kg
  8. Design Pressure: 0.25Mpa
  9. Design Temperature: 139℃

2. APPLICATION

The cabinet utilizes the physical characteristics of the saturated steam, which would release large amounts of latent heat and humidity during condensation, and with a period of time to keep the object at high temperature and most condition, the main protein of the bacteria would be solidified so that the bacteria can be killed.

The device is widely used in pharmaceutical, medical, scientific and other industries for the high temperature sterilization, cooling and drying process to the biological products, medical devices, sterile clothing, tools, utensils, media, and the other items.

3. CHARACTERISTICS

The main body is with horizontal rectangle double layer structure, the inside chamber is made of SUS30408 or SUS31608 stainless steel, the outer layer is made of the brushed decorative sheet, and the there is motorized door or sliding door for choose, pneumatic sealing, and the double door interlocking are strictly in accordance with the GSSD required.

The control system: adopt the Siemens PLC and Siemens touch screen.

The piping system: Adopt with the reliable Germany Burkert or GEMU pneumatic angle type valve, water ring vacuum pump and 1.22um high efficiency sterile medical grade filters, the pipe clamp adopts the quick connectors, the piping and the related spares are all according to the sanitation standard.

4. CHARACTERISTICS OF SOFTWARE

·With Germany Simens PLC platform independent research and development, human-Machine Interaction, convenient for operation.

·Software design and manufacture products in strict accordance with the technical requirements for the sterilization process.

·The Operating authority is divided into three levels to the manager, the technologist, and the operators.

· Program interlocked, by the program is running, the sealing door can not be open.

·All the alarm and the technical figures can be recorded and print.

·If the inner chamber is higher than the safety pressure, the door can not be open.

·Perfect product safety protection measures,4 level emergency treatment of abnormal state.

5. STERILIZING CYCLES

The sterilization cycle to the solid objects applied to the instruments, dressings, utensils and other items.

 

 

 

 

 

 

 

 

 

 

 

The sterilization to the fluid, applied to the fluid placed into the non-sealed media which can not bear the high heat and vacuum process.

 

 

 

 

 

 

 

 

 

 

 

 