CALORIMETER IC210

  1. Analysis Chamber with Patented Utility Model
  2. Gravimetrically Detection of Hydrogen Content in Samples (Patented Method)
  3. User-Friendly PC Calorimeter Control Software
  4. Water Circulator with Heating and Cooling Properties (Optional)
  5. Halogen Resistant Decomposition Vessel (Optional)
  6. Integrated Touch Screen Additional Recalculation Software
  7. Application Notes For Different Sample Types Excellent Service Support & Support Documents Education and Training Materials
  8. Spare Parts and Consumables

Description

How Calorimeter Works?
The sample to be analyzed is placed in the decomposition vessel resistant to high pressure. The vessel is placed in the analysis chamber filled with water, which is kept at a constant temperature without being affected by the external environment. The sample in the vessel is ignited by high pressure oxygen (30 bar) and electrodes. With the burning of the combustible sample, the temperature of the vessel increases and it starts to heat the water in the analysis chamber. By measuring the change in water temperature, the calorific value of the sample is calculated.

SPECIFICATION

Temperature Measurement Resolution 0.0001 K
Measuring Mode Isoperibol
Water Filling and Draining Automatic
Ignition Automatic
Analysis Duration < 16 min.
Preparation Time for Operator maximum 2 min.
Range of Measurement 40 000 J
Reproducibility RSD <0,1%
Operating Oxygen Pressure 30-40 bar
Input Power Max. 200 W
Rated Voltage 220V / 120V
Dimensions 498x678x396 mm
Protection Class III
Ambient Temperature 15-35 °C
Ambient Humidity < 85%
Frequency 50/60 Hz.
Protection Class According to DIN IP 20
Cooling Medium Water Circulator
Water Filter Included
Oxygen Filling Manual
Degasification Manual
Halogen (Decomposition) Vessel Optional
Analysis According to ISO 1928, ISO 18125, ISO 9831, ISO 1716, ASTM D5865, ASTM D5468

ASTM D4809, ASTM D240, ASTM E711, DIN 51 900

Interface USB
Languages

Water Circulator

EN/TR

Information

Operating Options Heating/Cooling
Temperature Range -20 / 100 °C
Bath Capacity 7 L
Temperature Stability ±0,03
Heating Capacity 1,1 kW
Cooling Capacity 0,25 kW
Power Requirements 220-240 V / 50-60 Hz
Dimensions

Software

292x423x620 mm

Information

Choosing Analysis Type Calibration/Standard
Operating on Sofware While Analysis Continues Yes
During Analysis Graphic Progress Yes
Analysis Graphic Output ±0,03
Calculation Gross/ Net Calorific Value
Excel Output Yes
Analysis Control Device Control/ Analysis Simulation
File Encryption Yes
User Registration Unlimited
After Analysis List and Review Analysis
Listing According to: Username Analysis Name, Analysis Date
Recalculation on Previous Analysis Yes
Service Authorization Full Authorization Log File Access
User Friendly Service Feedbacks Warnings and

Auto Problem Identification

Operating System Windows

 