Description
Installation and measurement OP-201
Single unit of the analyzer covers the display and the printing of measured value that are recorded in its main body, and can be easily hand-carried.
No more than one tester operator behind the wheel would be enough to conduct the free acceleration test to obtain the measured value stepping on the accelerator and using wired or wireless handheld terminal.
In supply of diversified basic PC software: PC program are provided in the way
to cover regulations from various countries and also ramified for 니ser’s purposes such as governmental agency’s use, inspection or repair of vehicle.
CATALOG : DOWLOND DISINI
Model | OP-201 |
---|---|
Measuring items | Smoke opacity (%, k [m-1]) RFM(option), ºC(option) |
Principle | Light extinction method (Partials-flow sampling type) |
Light source | Green LED(565nm) |
Detector | Photo diode |
Range | 0.0 ~ 100.0% (0.00 ~ 21.42m-1) |
Accuracy | Less than 1% |
Warm-up time | 3~6 minutes |
Display time | 4 times/sec |
Power | 220V/110VAC 50/60HZ |
Temperature | -10 ~ 40ºC |
Dimension | 450(W) x 200(D) x 245(425XH)mm |
Packing size | 470(W)x 380(D) x 300(H)mm |
Weight (Net/Gross) | 7kg / 10kg |
Option | RPM/ Oil temp, meter, Handheld terminal, Built-in printer, Standard filter, PC program |
*Specifications may very for performance and quality