Description
Test method: Kinematic viscosity is of primary importance in the design and selection of a wide range of petroleum products. Calibrated capillary viscometers are used to measure flow under gravity or vacuum at precisely controlled temperatures. Description: Constant temperature bath with advanced temperature control circuitry and integrated timing features for convenient, accurate glass capillary viscometry determinations. Microprocessor PID circuitry assures precise, reliable temperature control within ASTM specified tolerances throughout the operating range of the bath. Simple push-button controls and dual digital displays permit easy setting and monitoring of bath temperature. Two place calibration offset capability is provided. The bath accommodates seven glass capillary viscometers of various types. Viewing the viscometers is made easy by glare-free LED illumination inside the bath and a baffle that provides a background for easy viewing. Temperature control uniformity is assured by means of motorized stirrer which provides complete circulation without turbulence. Connection of the built-in cooling coil to tap water or a recirculating water chiller facilitates temperature control at ambient or below-ambient temperatures. Communications software (RS232, etc.) ramp-to-set and other enhanced features are available at an additional cost. Integrated Timing Features -The user can enter the viscosity constant for each viscometer on the front Touch Screen Control Panel and then get the test result in both efflux time and viscosity units automatically after stopping each timer. Timing function is displayed in 0.01 second resolution and is accurate within 0.01%. Bath Construction and Safety Features - Bath chamber is a clear borosilicate glass vessel enclosed in a polyester-epoxy finished steel housing. The top working surface has seven 2" (51mm) viscometer ports. Front viewing window assures safe, distortion-free viewing. Microprocessor temperature controller incorporates safety circuitry that interrupts power to the heaters in the event of an overtemperature condition or disconnection of the primary probe. For added safety, an adjustable redundant controller with separate sensor probe interrupts power if an overtemperature situation occurs. An integrated low-liquid sensor prevents operation of the bath if the bath liquid is not filled to the proper level and cuts off power should it fall below during operation. Both over-temperature and low liquid level circuits will latch and prevent further operation of the bath until the fault is removed. Accessories: Port Cover, Delrin® (7) Thermometer Holder Electrical Requirement: 115V 60Hz, Single Phase, 12.6A 220-240V 50/60Hz, Single Phase, 7.2A Dimension: lxwxh,in.(cm) 12" Bath: 20 ¼ x 15 ¼ x 24 ½ (51x39x62) 18" Bath: 20 ¼ x 15 ¼ x 30 ½ (51x39x77) Net Weight: 12" Bath Net Weight: 78 lbs (35.5kg) 18" Bath Net Weight: 90 lbs (41kg) Additional Accessories 378-025-C01 thru 378-700-C01 Cannon®-Fenske Viscometer Tubes, Size 25 thru 700 378-025-C02 thru 378-700-C02 Cannon®-Fenske Opaque Reverse Flow Viscometer Tubes, Size 25 thru 700 378-000-C03 thru 378-005-C03 Ubbelohde Viscometer Tubes, Size 0 thru 5 K23700-SFW-A Kinematic Viscosity Software K22090 Withdrawal Bulb K23311 Rubber Stopper for Viscometer Tube, pk/12 K23350 Universal Viscometer Holder, Rectangle K23351 Universal Viscometer Holder, Round K23363 Modified Koppers Viscometer Holder, Round K23381 Cannon-Fenske Routine Viscometer Holder, Round K23382 Ubbelohde Viscometer Holder, Round K23383 Cross-Arm Viscometer Holder, Round K23384 Cannon-Ubbelohde Semi-Micro Viscometer Holder, Round K23387 BS/IP/RF U-Tube Viscometer Holder, Round 355-001-001 White Mineral Oil, 1 Gallon 355-001-003 White Mineral Oil, 5 Gallon 250-000-120C ASTM 120C Thermometer, 40 °C Test Temperature 250-000-121C ASTM 121C Thermometer, 100 °C Test Temperature PT. Trias Nathomi Chemindo
JAKARTA-1-Wrapseal/Chemical Products
Jl Industri KAV 9-11 Komplek Griya Kemayoran Unit R106/SB03, Gunung Sahari Utara, Sawah Besar Jakarta Pusat 10720 DKI
Jakarta Telp 021-62302799 HP/WA: 081270868021; 08131810223
Email : triasnathomichemindo.pt@gmail.com; nimrod.sitohang@triasnathomichemindo.com
JAKARTA-2 Laboratory Equipment and Apparatus and Services.
Jl. Inspeksi PIK 2, Terusan Jalan Perancis No. 5, Blok C1 No 5 Tangerang 15211, Indonesia
Telp 021-39721789; HP/WA:08131810225, HP/WA: 081270868021
Email : triasnathomichemindo.pt@gmail.com; nimrod.sitohang@triasnathomichemindo.com
KOTA PEKANBARU
Jl. Jendral No.43E, Labuh Baru Timur, Kec. Payung Sekaki, Kota Pekanbaru, Riau 28291
Telp: +62761-8366395, HP: 081270868021
Email: nimrod.sitohang@triasnathomichemindo.com, triasnathomichemindo.pt@gmail.com
(Patokan, 1 KM dari Jalan Soekarno Hatta, Didepan Farrel motor Jl Jenderal Pekanbaru)
KOTA BATAM
Komplek Ruko Taman Niaga Sukajadi Blok K No.11 BATAM Centre, Telpon: 0778-4800510, HP:081270868021
Email: nimrod.sitohang@triasnathomichemindo.com, triasnathomichemindo.pt@gmail.com
(Patokan, Lurusan MEDILAB Batam Centre)





WhatsApp us
Reviews
There are no reviews yet.