Single Beam Atomic Absorption Spectrophotometer (8 Lamp Stand)

Atomic absorption spectrometry (AAS) is an easy, high-throughput, and inexpensive technology used primarily to analyze elements in solution. As such, AAS is used in food and beverage, water, clinical research, and pharmaceutical analysis.

The Atomic absorption spectrophotometer is completely controlled by a PC, which can be flexibly equipped with flame, graphite furnace atomizer, and highly automated atomic absorption spectrophotometer. Unique optical-mechanical design, safe and convenient flame system, advanced graphite furnace temperature control technology, optional buckle background technology, and various convenient functions provided by the workstation, to meet your pursuit of automatic and accurate measurement results. With more than 500 data self-storage and power storage functions.

 

Category: Tag:

Description

Single Beam Atomic Absorption Spectrophotometer (8 Lamp Stand)
The Atomic absorption spectrophotometer is completely controlled by a PC, which can be flexibly equipped with flame, graphite furnace atomizer, and highly automated atomic absorption spectrophotometer. Unique optical-mechanical design, safe and convenient flame system, advanced graphite furnace temperature control technology, optional buckle background technology, and various convenient functions provided by the workstation, to meet your pursuit of automatic and accurate measurement results. With more than 500 data self-storage and power storage functions.

Optional Accessories:

  1. Auto sampler
  2. Graphite Furnace
  3. Burner Head
  4. Glass atomizer
  5. Hydride Generator
  6. Chilled water unit
  7. Ventilating Hood ( 1.5 meters )

FEATURES:

  1. PC software control: can flexibly select the flame and graphite furnace atomizer (optional). All parameters of the instrument are
    set by computer software, and the program is automatically controlled.
  2. Three working modes can be selected: absorbance (continuous integration signal, peak height/peak area integration signal),
    concentration straightness, and flame emission intensity. It has four signal modes: atomic absorption, background absorption,
    background deduction correction, and emission intensity.
  3. Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though
    use the optical signal for a long term.
  4. Eight light stands can be changed automatically, with the functions of simultaneous preheating, automatic rotation switching,
    automatic ignition, and automatic optimization of the working conditions of hollow cathode lamps.
  5. Position adjustment: The ideal height and front and rear position of the flame burner are automatically set.
  6. Perfect safety interlock protection device: The system has alarm safety protection function for incorrect connection of
    combustion head, gas leakage, air underpressure, abnormal flameout, etc
  7. . Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong
    burner, leakage of the gas, under voltage of air and the abnormal flameout.
  8. Deuterium lamp and self-absorption background regulation. It has the functions of automatic wavelength scanning, automatic
    gain, background correction, automatic energy balance, and automatic peak search according to the peak search method
  9. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the
    analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
  10. Measuring method: flame absorption method and emission method.
  11. Result printing: parameter printing, data result printing and diagram printing.

SPECIFICATION:

  1. Wave length range : 190 – 900nm
  2. SPECTRAL BANDWITH: 0.1, 0.2, 0.4, 1.0 and 2.0nm
  3. Accuracy of the wavelength; ±0.15nm
  4. Receptivity of the wavelength: <0.04nm
  5. Base line stability: <0.002A/30min (Cu)
  6. Characteristic viscosity: 0.02pg/ml/1% (Cu)
  7. Checking limit: 0.004pg/ml (C)
  8. Preciseness: 0.5%
  9. Grating: 1800 lines/mm
  10. Inflamer: All-metal titanium burner
  11. Atomizer: Effective glass atomizer
  12. Lamp stand: 8

Flame System

  1. Acetylene air burner: 100mm
  2. Ignition dynamic baseline drift: <0.006A/30min
  3. (Cu) Characteristic viscosity: <0.025pg/ml/1%
  4. Related standard deviation of the accuracy: <0.5%(Cu, absorbance>0.8A) (detection limit Cu<0.008pg/ml)
  5. Safety system: Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

Graphnite Furnace

  1. The highest temperature: 3000°C
  2. The largest temperature rising speed: >2000°C/S
  3. Characteristic quantity: Cd<0.5xl0-12g Cu<0.5xl0-llg
  4. Accuracy: Cu<3% Cd<3%
  5. Safety system: Over current protection Low air pressure alarm /protection Low cooling water flow alarm/protection
  6. Power source and power: 220V±22V AC 7000W

STANDARD ACCESSORIES

  1. PC workstation
  2. HP ink-jet printer
  3. Oil free Air compressor
  4. Acetylene reducing valve
  5. Cu Hollow cathode lamp
  6. Air filter

COMPLETE AUTOMATIC CONTROLLING SYSTEM
With the help of the software, the following can be easily achieved.
1. Selection of the element lamp
2. Up-down-front-rear adjustment of the lifter
3. Adjustment of the optical energy
4. Selection of the slit
5. Determination of wavelength scanning and peak searching
6. Selection of the atomizer
7. Setting of the background deduction method
8. Controlling of the gas flow
9. Automatic flaming and flaming out
10.Setting of the graphite furnace testing method

 

ADVANCED GRAPHITE FURNACE TEMPERATURE CONTROLLING
TECHNOLOGY
The bringing in of PTD technology can effectively overcome the influence on the temperature rising process caused by the voltage
fluctuation and the resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling
technique can make more accurate and reliable testing data
The fast heating capacity can improve the flexibility of the elements further
Use the ordinary power source of 220V without need of dynamic power of 380V
The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples
Three grades adjustable gas flow can accustom to more application needs
Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage
and measuring error.

SAFE, RELIABLE AND CONVENIENT FLAME SYSTEM
EPC can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily
Efficient a tomi zati on s ys tern enables a higher Sensitivity. The whole operation system has a high security as the fire safety system can
alarm whenever the electrici- ty is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it
will automatically turn off the gas, prohibit temper ing. Thus it keeps the operation people and equipment from harm and damage.

MULTI-FUNCTIONAL SOFTWARE WORKSTATION

  1. A w o r k s t a t i o n t h a t i s s u p p o r t e d W I N D OW S XP/20 00/NT
  2. The rich menu brings great convenience to the use of customer
  3. Convenient conversion between different menus makes the operation more easily
  4. Various analytical correction methods provide the users more choices
  5. Basic default parameter settings enable even the beginners can do the normal operation
  6. Flexible sto r age, e ditin g and p rin tin g m e th ods give the user largest support