JUAL ETHYLENE ANALYSER for FLOWERBULB STORAGE



ETHYLENE ANALYSER for FLOWERBULB STORAGE

ETHYLENE ANALYSER for FLOWERBULB STORAGE

Ethylene (ISO name Ethene) coming from sour flower bulbs is very harmfull for flower bulbs during the period of preservation. To high concentrations Ethylene can lead to gumming, loss of weight, separation of the flower bulbs and flower drying out. Out of fear for Ethylene one often ventilates more than necessary. This costs a lot of energy and leads to drying out of the flower bulbs.

 

ETHYLENE ANALYSER for FLOWERBULB STORAGE

The new MACView® Ethylene Analyser for flowerbulbs is capable of accurate and reliable measuring of Ethylene, even at extreme low concentrations. Through interfacing the Ethylene signal to the computer of the storage, Ethylene values are measured central in the storage and the ventilation valve is activated when needed. Due to this there is no more ventilation than needed. At the same time energy is saved and loss of quality prevented. During storage and afterwards with one push on the button the history of the Ethylene values of a storage can be visualised. This information is very valuable for the guarantee of a high quality storage. The MACView® Ethylene Analyser for flowerbulbs pays itself back within a couple of years only through the energy saving. Added to this are the financial advantages of a guaranteed storage with save Ethylene values and minimal loss of weight.

 

 

ETHYLENE ANALYSER for FLOWERBULB STORAGE

 

TECHNICAL SPECIFICATION

 

Kinds of sensors Ethylene sensor and Actellic-detection sensor for detection and switching possibilities to prevent damage by agressive gas or Actellic.
Interface to climate computers 4-20mA for Ethylene signal, to your choice adjustable potential free digital input port for message of the climate computer “Start gasses”.To your choice digital RS232 or RS485 output port to PC.
Material housing High quality stainless steel , class of sealing IP65.
Standards NEN-EN-IEC 61000-6-1 t/m 4CE
Program modi MeasurementBatchingStand byRinsing
Signals/warnings ppb hysteresis adjustable on relais (programmable for every function)Analogue output 4-20mA (programmable for every function)Several status messages : power, failure, relais 1
Acceptance of warnings With accept button on front side
Registration Internal database with date and time clock for over 6700 records readable with addedPC software
Service connection RS232 and RS485 interface
Powerconnection 230 VAC 30W
Operating temperature -10 / +60 degree CelciusRelative humidity 5 till 95%, not condensed
User interface Intuitive menu with graphic display and backlight
Dimensions W 525 x H 250 x D 154 mm
Mounting Housing mountable to the wall with mounting eyes
Software MACregister® software with diagrams, tables data and time standard suitable for Windows 95, 98, NT, 2000, ME and XP