P810 P810A P850 P850A Automatic Polarimeter

P800 Polarimeter includes built-in Peltier precise temperature control system. P Series Polarimeter with automatic photoelectric inspection technology and WINDOWS HMI system, boasts accurate and reliable measurement, convenient operation and so on. By detecting the optical rotation, the density, content and purity of substances etc. can be analyzed and determined. It’s widely used in medicine, petroleum, food, chemicals, flavors, spices, sugar marking, other industries and universities and research institutes.

P800 Polarimeter Characteristics :

  • Large color touch screen display and innovative WINDOWS software interface give extremely convenient device operation and data acquisition.
  • High brightness LED lights with service life exceeding 100000 hours.
  • A variety of measurement modes are optional, without using complicated manual calculation.
  • Extremely large storage capacity can store up to 1000 groups of data informationautomatically.

Automatic Polarimeter P850/P850A

includes built-in Peltier precise temperature control system. P series Polarimeter with automatic photoelectric inspection technology and WINDOWS HMI system,boasts accurate and reliable measurement, convenient operation and so on. By detecting the optical rotation, the density, content and purity of substances etc. can be analyzed and determined. It’s widely used in medicine, petroleum, food, chemicals, flavors, spices, sugar making, other industries and universities and research institutes.

Hanon P800 polarimeter brings an economic solution for client for teaching and the budget is limited.It’s equipped with automatic optical zero balance,Infrared c o u n t i n g r e c e i v e s , M i c r o c o m p u t e r i n f o r m a t i o n processing,The LCD backlight digital display with clear reading, visual comfort, long life,The output information includes the three times reading, average value, sample batch number, operator, date of operation.

Ultra long life light source It adopt High brightness LED lights with service life exceeding 100000 hours, less time ready for use, save your cost and time.

Automatic Calibration

P810A/P850A built in automatic calibration system, it provides much higher accuracy result, much easier for calibration.

Automatic temperature; Control system P850/P850A adopts peltier temperature control system, make sure the whole testing w i t h a c c u r a c y a n d constant temperature.

P800 Polarimeter Detailed Spesification :

  • Measuring Range ±45◦ Arc ±120◦ Z
  • Min Reading 0.001◦ (Optical Rotation)
  • Accuracy ±0.02◦
  • Repeatibility (Standard Deviation) 0.002 (Optical Rotation)
  • Measurable sample Min Transmittance 1%
  • Working Wavelength 589.3nm (Sodium D Spectrum)
  • Dimention (wxdxh)mm 605x320x212

P810 Polarimeter Detailed Spesification :

  • Measuring Range ±89.9 Arc ±259◦Z
  • Min Reading 0.001◦ (Optical Rotation)
  • Accuracy ±0.01◦ (-45◦≤Optical Rotation≤+45◦) – ±0.02◦ (Optical Rotation<-45◦ Or Optical Rotation >+45◦)
  • Repeatibility (Standard Deviation) 0.002 (Optical Rotation)
  • Measurable sample Min Transmittance 1%
  • Working Wavelength 589.3nm
  • Dimention (wxdxh)mm 708x330x287

Detail Produk

Kategori : Polarimeter
P810 P810A P850 P850A Automatic Polarimeter

P800 Polarimeter includes built-in Peltier precise temperature control system. P Series Polarimeter with automatic photoelectric inspection technology and WINDOWS HMI system, boasts accurate and reliable measurement, convenient operation and so on. By detecting the optical rotation, the density, content and purity of substances etc. can be analyzed and determined. It’s widely used in medicine, petroleum, food, chemicals, flavors, spices, sugar marking, other industries and universities and research institutes.

P800 Polarimeter Characteristics :

  • Large color touch screen display and innovative WINDOWS software interface give extremely convenient device operation and data acquisition.
  • High brightness LED lights with service life exceeding 100000 hours.
  • A variety of measurement modes are optional, without using complicated manual calculation.
  • Extremely large storage capacity can store up to 1000 groups of data informationautomatically.

Automatic Polarimeter P850/P850A

includes built-in Peltier precise temperature control system. P series Polarimeter with automatic photoelectric inspection technology and WINDOWS HMI system,boasts accurate and reliable measurement, convenient operation and so on. By detecting the optical rotation, the density, content and purity of substances etc. can be analyzed and determined. It’s widely used in medicine, petroleum, food, chemicals, flavors, spices, sugar making, other industries and universities and research institutes.

Hanon P800 polarimeter brings an economic solution for client for teaching and the budget is limited.It’s equipped with automatic optical zero balance,Infrared c o u n t i n g r e c e i v e s , M i c r o c o m p u t e r i n f o r m a t i o n processing,The LCD backlight digital display with clear reading, visual comfort, long life,The output information includes the three times reading, average value, sample batch number, operator, date of operation.

Ultra long life light source It adopt High brightness LED lights with service life exceeding 100000 hours, less time ready for use, save your cost and time.

Automatic Calibration

P810A/P850A built in automatic calibration system, it provides much higher accuracy result, much easier for calibration.

Automatic temperature; Control system P850/P850A adopts peltier temperature control system, make sure the whole testing w i t h a c c u r a c y a n d constant temperature.

P800 Polarimeter Detailed Spesification :

  • Measuring Range ±45◦ Arc ±120◦ Z
  • Min Reading 0.001◦ (Optical Rotation)
  • Accuracy ±0.02◦
  • Repeatibility (Standard Deviation) 0.002 (Optical Rotation)
  • Measurable sample Min Transmittance 1%
  • Working Wavelength 589.3nm (Sodium D Spectrum)
  • Dimention (wxdxh)mm 605x320x212

P810 Polarimeter Detailed Spesification :

  • Measuring Range ±89.9 Arc ±259◦Z
  • Min Reading 0.001◦ (Optical Rotation)
  • Accuracy ±0.01◦ (-45◦≤Optical Rotation≤+45◦) – ±0.02◦ (Optical Rotation<-45◦ Or Optical Rotation >+45◦)
  • Repeatibility (Standard Deviation) 0.002 (Optical Rotation)
  • Measurable sample Min Transmittance 1%
  • Working Wavelength 589.3nm
  • Dimention (wxdxh)mm 708x330x287