Description
FEATURES:
- The body of the low-temperature test chamber is processed and formed by CNC machine tools, with a beautiful appearance and a handle without reaction, which is easy to operate.
- The inner liner of the box is made of imported stainless steel (SUS304) mirror panel, and the outer liner of the box is sprayed with A3 steel plate, which increases the appearance texture and cleanliness.
- The large observation window is equipped with a lighting lamp to keep the inside of the box bright, and the built-in tempered glass in the heating element is used to clearly observe the situation inside the box at any time.
- Equipped with a test hole with a diameter of 50mm, which can be used for external test power lines or signal lines.
REFERENCES:
- GB/T 2423.1-2008/IEC 60068-2-1 low temperature test method
- GB/T 2423.2-2008/IEC 60068-2-2 high temperature test method
- GB/T 2423.3-2008/IEC 60068-2-78 constant damp heat test method
- GB /T 2423.4-2008/IEC 60068-2-30 Alternating Damp Heat Test Method
- GJB 150.3A-2009 Military Equipment Laboratory Environmental Test Method High Temperature Test Method
- GJB 150.4A-2009 Military Equipment Laboratory Environmental Test Method Low Temperature Test Method
- GJB 150.9A -2009 Environmental test methods for military equipment laboratories Damp heat test
- GJB 360B-2009 Test methods for electronic and electrical components
- GB/T 5170.2-2008 Test methods for environmental test equipment for electrical and electronic products Temperature test equipment
- GB/T 5170.5-2008 Environmental test equipment for electrical and electronic products Inspection method Damp heat test equipment
SPECIFICATIONS:
Product Name | Ultra-low Temperature Test Chamber | ||||
Product Number | TR-UTC100 | TR-UTC250 | TR-UTC500 | TR-UTC1000 | |
Inner box volume | L/L | 100 Liter | 250 Liter | 500 Liter | 1000 Liter |
Inner box size | W*D*H (cm) | 45×45×50 | 60×60×70 | 75×75×90 | 100×100×100 |
Dimensions | W*D*H (cm) | 65×100×145 | 80×120×170 | 95×140×190 | 120×150×195 |
Performance | Temperature range | A. -90℃~+50℃ B. -120℃~+50℃ C. -150℃~+50℃ D. -170℃~+50℃ | |||
Humidity range | 20%~98%RH | ||||
Temperature fluctuation | ≤±0.5℃ | ||||
Humidity fluctuation | ≤±2%RH | ||||
Temperature uniformity | ≤2.0℃ | ||||
Temperature deviation | ≤±2.0℃ | ||||
Humidity Deviation | Humidity>75%RH: ≤+2,-3%RH; Humidity<75%RH: ≤±5%RH | ||||
Cooling time | +25℃~-90℃≤2H +25℃~-120℃≤3H +25℃~-150℃≤4H +25℃~-170℃≤5H |
||||
Cooling method | Compressor Refrigeration | ||||
Cooling method | F, air cooling W, water cooling |