Bio Hazard Safety Cabinet Class II Type A2-Platinium Models

  1. BIO-HAZARD SAFETY CABINETS PLATINIUM TYPE A2.
  2. Biohazard Safety Cabinet – Floor Standing Type
  3. In compliance with ISO 14644-1, ISO Class 5 (Class 100)standards
  4. 70% of the air is recirculated and 30% of the air is exhausted.
  5. PLATINIUM MODELS LCB-903B-A2, LCB-1203B-A2, LCB-1503B-A2, 
  6. CLASS II TYPE-A2
  7. ada 4 Air Volume (approx) yaitu: 980 m² / h, 1350 m² / h, 1700 m² / h, 2030 m² / h
  8. Microprocessor Digital Controller with LCD Display

Description

Features

  1. In compliance with ISO 14644-1, ISO Class 5 (Class 100)standards
  2. 70% of the air is recirculated and 30% of the air is exhausted
  3. Pressure Gauge
    Is installed as standard to check filter lifetime status.
  4. Tempered Safety Glass
    Door with Safety Alarm in case the door is opened above the proper height.
  5. High Efficiency
    Dual Inlet Blower is installed to provide reduced noise and vibration.
  6. Utility Device
    includes npt 1/4 air valve, gas valve, 110 V or 220V Electric socket (selectable), DOP test valve, UV lamps and FL lamps are installed as standard
  7. Stainless Steel Single
    Piece Dished Work Space for easy cleaning and to prevent contaminants
  8. Arm Rest
    Provides comfortable user working posture
  9. Paper Catch
    Is installed as standard
  10. Microprocessor Digital Controller with LCD Display [ LCD Display, Filter Lifetime Check, Alarm, Lamp on/off,
    Fan on/off status indicator, Mode, Lamp on/off, Fan on/off Button, Setting Values
  11. The controller enables:
    Velocity setting, alarms, filter lifetime check, UV&FL lamp on/off, UV lamp timer, room temperature, present date and time
  12. Control Function; MODE UV time setting, MODE Alarm for Air Velocity, MODE Air Velocity Set, MODE Alarm for Filter, MODE Alarm for Door Open, MODE Display for Working.
  13. [Specifications can be changed without prior notice for quality improvement, Custom made order is available]

SPECIFICATION:

MODELSLCB-903B-A2 LCB-1203B-A2 LCB-1503B-A2 LCB-1803B-A2
Stand ModelsLST-0103B LST-0123B LST-0153B LST-0183B
DimensionsDimensions
(W×D×Hmm
Interior 890 x 600 x 635 1190 x 600 x 635 1490 x 600 x 635 1790 x 600 x 635
Exterior1050 x 800 x 1880 1350 x 800 x 1880 1650 x 800 x 1880 1950 x 800 x 1880
Maximum Door Opening Height 540 mm
540 mm
540 mm
540 mm
Working Door Opening Height
200 mm
200 mm
200 mm
200 mm
ControllerMicroprocessor Controller with Air velocity set, Low air speed alarm, Record working time and date set, Temperature monitoring, UV & FL Lamp operationMicroprocessor Controller with Air velocity set, Low air speed alarm, Record working time and date set, Temperature monitoring, UV & FL Lamp operationMicroprocessor Controller with Air velocity set, Low air speed alarm, Record working time and date set, Temperature monitoring, UV & FL Lamp operationMicroprocessor Controller with Air velocity set, Low air speed alarm, Record working time and date set, Temperature monitoring, UV & FL Lamp operation
Double Inlet Centrifugal Blower 340~400 w 440~680 w 480~750 w 480~750 w
Air Volume (Approx.)
34 ㎥/min 50 ㎥/min 57 ㎥/min 57 ㎥/min
Filter TypeStandard: ULPA U15 Filter, Aluminum fraimed particle removal 99.9999% ISO Class 3, Class 10
Option - PTFE ULPA Filter
Standard: ULPA U15 Filter, Aluminum fraimed particle removal 99.9999% ISO Class 3, Class 10
Option - PTFE ULPA Filter
Standard: ULPA U15 Filter, Aluminum fraimed particle removal 99.9999% ISO Class 3, Class 10
Option - PTFE ULPA Filter
Standard: ULPA U15 Filter, Aluminum fraimed particle removal 99.9999% ISO Class 3, Class 10
Option - PTFE ULPA Filter
Air flow
Down flow Standard average 0.3 m/sec, Range 0.25~0.35 m/sec Standard average 0.3 m/sec, Range 0.25~0.35 m/sec Standard average 0.3 m/sec, Range 0.25~0.35 m/sec Standard average 0.3 m/sec, Range 0.25~0.35 m/sec
In flow Standard average 0.5 m/sec, Range 0.45~0.65 m/sec Standard average 0.5 m/sec, Range 0.45~0.65 m/sec Standard average 0.5 m/sec, Range 0.45~0.65 m/sec Standard average 0.5 m/sec, Range 0.45~0.65 m/sec
Noise Level SoundStandard < 60 dB, Range 56~65 dB(A)
Standard < 60 dB, Range 56~65 dB(A)
Standard < 60 dB, Range 56~65 dB(A)
Standard < 60 dB, Range 56~65 dB(A)
IlluminationFL Lamp 20 W x 1 EA FL Lamp 20 W x 1 EA FL Lamp 40 W x 1 EA FL Lamp 40 W x 1 EA
UV DisinfectionUV Lamp 15 W x 2 EA UV Lamp 15 W x 2 EA UV Lamp 15 W x 3 EA UV Lamp 15 W x 3 EA
Utility Devicesnpt 1/4 Air/Gas Valve, Vaccum Valve, 110 V or 220 V Electric Socket(selectable), PAO test Valvenpt 1/4 Air/Gas Valve, Vaccum Valve, 110 V or 220 V Electric Socket(selectable), PAO test Valvenpt 1/4 Air/Gas Valve, Vaccum Valve, 110 V or 220 V Electric Socket(selectable), PAO test Valvenpt 1/4 Air/Gas Valve, Vaccum Valve, 110 V or 220 V Electric Socket(selectable), PAO test Valve
MaterialInteriorStainless steel grade 304 with hair lined finish
Stainless steel grade 304 with hair lined finish
Stainless steel grade 304 with hair lined finish
Stainless steel grade 304 with hair lined finish
ExteriorStandard - Epoxy powder coated electro galvanized steel
Option - Stainless steel grade 304
Standard - Epoxy powder coated electro galvanized steel
Option - Stainless steel grade 304
Standard - Epoxy powder coated electro galvanized steel
Option - Stainless steel grade 304
Standard - Epoxy powder coated electro galvanized steel
Option - Stainless steel grade 304
DoorSlope 7° T. 5mm tempered safety glass sliding doorSlope 7° T. 5mm tempered safety glass sliding doorSlope 7° T. 5mm tempered safety glass sliding doorSlope 7° T. 5mm tempered safety glass sliding door
Electric Supply110 V 60 Hz or 220 V 50/60 Hz described order110 V 60 Hz or 220 V 50/60 Hz described order110 V 60 Hz or 220 V 50/60 Hz described order110 V 60 Hz or 220 V 50/60 Hz described order
Net Weight (Approx.)
Cabinet280 kg 250 kg 290 kg 330 kg
RemarksSpecifications can be changed without prior notice for quality improvement.Specifications can be changed without prior notice for quality improvement.Specifications can be changed without prior notice for quality improvement.Specifications can be changed without prior notice for quality improvement.
DISTRIBUTOR, SALES AND SERVICESPT. TRIAS NATHOMI CHEMINDOPT. TRIAS NATHOMI CHEMINDOPT. TRIAS NATHOMI CHEMINDOPT. TRIAS NATHOMI CHEMINDO

Reviews

There are no reviews yet.

Be the first to review “Bio Hazard Safety Cabinet Class II Type A2-Platinium Models”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

WhatsApp WhatsApp us