A3AFG Atomic Absorption Spectrophotometer

Atomic absorption spectrometry (AAS) is an easy, high-throughput, and inexpensive technology used primarily to analyze elements in solution. As such, AAS is used in food and beverage, water, clinical research, and pharmaceutical analysis. A3AFG Fully Combined automated Flame & Graphite Furnace Atomic Absorption Spectrophotometer

Spectrometer System

  1. Wavelength range 185nm -910nm
  2. Light Source Hollow cathode lamp (HCL), Deuterium Arc lamp (D2)
  3. Modulation Square Wave Pulse
  4. Modulation frequency 100Hz Self reversal (SR) background, 400Hz Deuterium Arc (D2) background

Monochromator

  1. Grating 1800 grooves/mm diffraction grating
  2. Blazed Wavelength 250nm
  3. Focus 300nm
  4. Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (Software selectable)
  5. Scan mode Automatic
  6. Photometric Type Single Beam
  7. Wavelength Accuracy ± 0.15nm
  8. Wavelength Resolution 0.2nm ± 0.02nm
  9. Wavelength Reproducibility < 0.05nm
  10. Baseline Stability 0.005Abs/30min
  11. Background Correction Deuterium Arc (D2) 1.0Abs, Self Reversal (SR) 3.0Abs

Flame Analysis

  1. Flame Types Air/Acetylene, Nitrous Oxide/Acetylene, Air/Propane (LPG)
  2. Sensitivity (Cu) 2ug/ml Absorption >0.28Abs
  3. Characteristic : Concentration Cu < 0.02ug/ml, Ba < 0.15mg/ml (N20/Acetylene)
  4. Detection Limit Cu < 0.004ug/ml
  5. Repeatability Cu < 0.7% (Air/Acetylene Flame) Ba < 1.0% (Nitrous Oxide/Acetylene Flame)
  6. Burner heads Titanium Alloy
  7. Nebulizer High efficiency glass, Acid proof available as an option
  8. Pre-mix Chamber Corrosion Resistant
  9. Atomizer Selection Automatic changeover (A3FG), Manual (A3F)
  10. Safety Features Burner identification, Flame Sensor, Gas Leak Sensor, Low Gas Pressure Sensor, Drain Trap, Sensor, Power Loss Protection

Graphite Furnace Analysis

  1. Graphite Head Transversally Heated
  2. Temperature Range Ambient – 3000 0C
  3. Heating Program Up to 10 steps. Drying, Ashing, Atomization, Cleaning
  4. Feedback Voltage and Optical temperature control feedback
  5. Sensitivity (Cu) 50ng/ml Absorption > 0.40Abs
  6. Detection Limit Cd < 0.004ng/ml
  7. Repeatability Cu < 2.0%, Cd < 2.0%
  8. Graphite Tubes Pyrolytically Coated with Platform Sample Size Up to 20ul
  9. Graphite Cooling Water Circulator Available
  10. Safety Features Argon Pressure Sensor, Water Flow Sensor, Over Temperature Sensor, Broken Tube Protection

Data Processing

  1. PC System PC, Windows
  2. Operating System Operating Program AA Win 3.0 software
  3. Analytical Methods Flame AA, Flame AE, Graphite Furnace, Hydride Generation Readout Mode Continuous, Peak Height, Peak Area
  4. Calibrations Multi-Standard Calibration, Standard Addition, Interpolation
  5. Data Storage Analytical results, instrument and measurement parameters, signal profile, calibration curve

Power Requirements

  1. Main Unit 220VAC 50/60Hz
  2. Graphite Power Supply 220VAC 50/60Hz Instantaneous power 7KW

Dimensions

  • Main unit 110cm x 54cm x 54cm 75Kg
  • Graphite Power Supply 50cm x 54cm x 54cm 70Kg
Category: Tag:

Description

The A3 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications including:

  • Agricultural
  • Environmental
  • Metal
  • Geological
  • Pharmaceutical
  • Clinical
  • Food
  • Mining
  • Petrochemical
    The versatile instrument is available in three configurations:
    A3F – The Instrument is equipped with a flame atomizer only. The positioning of which is fully controlled by the embedded computer system and AA-Win 3.0 software. Three flame options are available to the user with the Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O

/Acetylene and the Air/LPG(Natural gas) are available as an option for the more demanding of elements. All three flame configurations offer coded burner for full safety protection. A3G -The instrument is equipped with a Graphite Furnace Atomizer only. The graphite head is fixed into the optical pathtomaximise performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique. A3FG -The instrument is equipped with both Flame Atomizer and Graphite Atomizer as described above. Both configurations are installed into the instrument and can be changed over by a simple selection in the versatile AA-Win 3.0 software.

FEATURES & FUNCTION

  1. PC System is used to control the instrument. Preinstalled AA-Win 3.0 software, user manuals, cook book and Windows operating system.
  2. AA-Win 3.0 software provides full control of the instrument and autosampler with easy method change for each technique.
  3. Automatic 8 Hollow Cathode lamp turret controlled and optimized by the AA-Win 3.0 software. Operating lamp current and warm-up lamp current can be individually controlled to eliminate drift commonly associated with lamp warming.
  4. D2 lamp background correction system fitted as standard to all configurations. High energy D2 lamp and adjustable beam splitter mirror are optimized by the AA-Win 3.0 software.
  5. Self Reversal background correction system fitted as standard to all configurations. The high performance background system uses the same hollow cathode lamp as installed for the analysis. Minimum extra components are required and optical alignment is very simple. Self Reversal can be used for any element at any wavelength making it extremely versatile.
  6. High precision minimal optics ensures maximum light throughput to the computer controlled Czerny-Turner
    monochromator.
  7. A universal autosampler is available as an optional accessory which is conveniently mounted on the front of theA3instrument.
  8. Absorption and Emission modes are standard features in the AA-Win3.0 software as well as peak height, peak area, sequential and manual integration modes. Air/Acetylene
  9. The Air/Acetylene flame uses a 100mm single slot burner for the standard configuration.
  10. The high sensitivity (Cu 2ppm >0.280abs) is due to the efficiency of the fixed position glass nebulizer fitted as standard Antacid resistant replacement is available as an option.
  11. The flame can be easily set from blue lean flame through stoichiometric to fuel rich by means of computer control.

N2O/Acetylene

  1. The N2O/Acetylene flame uses a 50mm single slot burn- er and is available as an optional extra.
  2. This flame configuration is used to measure elements less prone to ionization such as: Aluminium, Tin, Titanium, Calcium,Vanadium and Molybdenum.
  3. Switching from Air/Acetylene to N2O/Acetylene to Flame Off is fully controlled by the AAWin3.0 software. Air/Propane(LPG)
  4. This flame uses a 3 slot burner and with the Iowpressure requirement it is also much safer to operate.
  5. Due to the Iow temperature of the flame it is ideal for analysing alkali metals such as: Potassium, SodiumandLithium, especially when used in the emission mode.
  6. Some remote areas of the world have difficulty obtaining Acetylene gas of a high enough purity to operatetheflamecorrectly, LPG can give a real alternative and offer comparable results for most elements throughout the wavelengthrange. FLAME ATOMISER FEATURES
    The flame atomizer offers three flame options: Air/acetylene is the standard configuration with the N2O/ acetylene and Air/LPG as options. SAFETY

FEATURES

  • Pressure monitoring for all gases
  • Burner Identification
  • Flame sensor
  • Drain Trap level Sensor
  • Gas Leak Detector
  • Over Pressuring Premix
  • Safety Cut off Switch

Reviews