Autodave / Sterilizer
Drying Oven
Environmental Test Chamber
Fume Hood / Safety Cabinet
Growth Chamber
Hach
Hotplate Stirrer
Incubator
Merck
Milwaukee
Others
Shaking Incubator
Storage Chamber / Freezer
Thermal Shock Tester
Water Bath
Water Purication System
product
 
   
REFRIGERATION AND AIR CONDITIONIG

RAC1
Labtech has designed a special flexible training system for the teaching of refrigeration and air conditioning
electrical controls. The program covers the operation, use and wiring of refrigeration and air conditioning
controls, compressors, electrical motors and basic electrical installation. It consists of real industrial components
mounted on to clear plexiglass panels which are then inserted into the special frame. This allows the student to
quickly assemble the components into various types of operational systems and explore their functions and
characteristics.
This trainer is not only ideal for exposing and giving practice in the basic of refrigeration and air con controls
but also can be used for making up special demonstrations of a variety of control systems to match specific
training programs. Complete systems can be mocked up or the controls can be connected to other installations
or trainers to provide additional features.
All electrical connections of the components are brought out to 4 mm heavy duty terminals. Connections are
made with stackable electrical test leads, which allow the student to make quick connections and easy
measurements. Refrigerant connections can also be made with flexible hoses in order to create fully operational
systems. A variety of modules are available to suit particular training requirements. Student exercise
sheets are including to covering the components and basic electrical connections.
ITEM : REFRIGERATION AND AIR CONDITIONIG
ELECTRICAL CONTROLS
1. A/C & Ref. Controls (RAC-ACA)
RAC-ACA-1 Low Voltage Thermostat
RAC-ACA-2 220 VAC Thermostat
RAC-ACA-3 Electronic Thermostat
RAC-ACA-4 Low Pressure Control
RAC-ACA-5 High Pressure Control
RAC-ACA-6 Fan Control Switch
RAC-ACA-7 Electric fan (for evaporator or
condenser)
RAC-ACA-8 Oil Pressure Switch
RAC-ACA-9 Electric Heat Sequencer
RAC-ACA-10 Electric Solenoid Valve
RAC-ACA-11 Defrost Cycle Timer, 220VAC
RAC-ACA-12 Compound Gauge, Low Side
RAC-ACA-13 Pressure Gauge, High Side
RAC-ACA-14 Hygrostat
RAC-ACA-15 Reverse Cycle Solenoid
RAC-ACA-16 Water Make-up Valve
RAC-ACA-17 Water Pump For Reverse Cycle
chiller system
2. Compressors & Ref. Components (RAC-ACB)
RAC-ACB-1A 1 Hp Hermetic Compressor
RAC-ACB-1B ½ Hp Hermetic Compressor
RAC-ACB-1C ¼ Hp Hermetic Compressor
RAC-ACB-1D 1/5 Hp Hermetic Compressor
RAC-ACB-2 1 Hp Semi-Hermetic Compressor
RAC-ACB-3 1 Hp Open Compressor
RAC-ACB-4 Operational Unit which consists
of an evaporator, condenser,
filter/drier, fans for evaporator &
condenser, connection ports to
connect to the compressors.
3. Electrical Motors (RAC-ACC)
Note: Electrical Motors have their connections
brought out to 4 mm terminals in order
to fit in with the training systems.
RAC-ACC-1 Capacitor Start Motor, 1/3 Hp, 1-phase
RAC-ACC-2 Dual Speed Induction Motor, 1/3
Hp, 3-phase
RAC-ACC-3 Ref. Multi function Motor, 1/3 Hp,
1-Phase
RAC-ACC-4 Capacitor Start, Capacitor Run
Motor, 1/3 Hp, 1 Phase
RAC-ACC-5 Induction Motor, 3 Phase
RAC-ACC-6 Split Phase Motor, 1/3 Hp, 1-phase
RAC-ACC-7 Universal Motor AC/DC
4. Electrical devices & Controls (RAC-ACD)
RAC-ACD-1 Current Relay
RAC-ACD-2 Potential Relay
RAC-ACD-3 Start Capacitor (2 pcs)
RAC-ACD-4 Run Capacitor (2 pcs)
RAC-ACD-5 CAM Switch, Start Stop, 3 phase
RAC-ACD-6 Toggle Switch, DPST
RAC-ACD-7 Toggle Switch, TPST
RAC-ACD-8 Selector Switch
RAC-ACD-9 Motor Starter
RAC-ACD-10 Push Button Switch, 1NO-1NC, 2 units
RAC-ACD-11 Variable Power Control (Dimmer)
Switch
RAC-ACD-12 Rheostat, 1 phase
RAC-ACD-13 Three Phase disconnect
RAC-ACD-14 Single Phase disconnect
RAC-ACD-15 Control Transformer, 220 VAC
primary, 24 VAC Secondary
RAC-ACD-16 Control Relay, 2NO - 2NC, 24 VAC
RAC-ACD-17 Solid State Relay
RAC-ACD-18 Pilot Light 220 VAC, Set of 4
RAC-ACD-19 Pilot Light 24 VAC, Set of 2
RAC-ACD-20 Two Pole Magnetic Contactor,
220VAC, 1 phase
RAC-ACD-21 Two Pole Magnetic Contactor, 24
VAC, 1 phase
RAC-ACD-22 Three Pole Magnetic Contactor, 3 phase
RAC-ACD-23 Four Pole Magnetic Contactor, 3 phase
RAC-ACD-24 Thermal Overload, 1 Phase
RAC-ACD-25 Thermal Overload, 3 Phase
RAC-ACD-26 Timer, 5 minutes
RAC-ACD-27 Switching Relay, 24 VAC coil
RAC-ACD-28 Circuit Breaker, 16A, 3 Phase
RAC-ACD-29 Circuit Breaker, 10A, 1 Phase
RAC-ACD-30 Trouble shooting Fault Module, 4
switches
5. Accessories: (RAC-ACE)
RAC-ACE-1 3 level Bench Top Rack for
mounting panels
RAC-ACE-2 3 level Mobile Rack for mounting
Panels
RAC-ACE-3 Set of Connection Leads
RAC-ACE-4 Set of Refrigerant Hoses for
interconnections
RAC-ACE-5 Hand valve (1/4" or 3/8")
RAC-ACE-6 Fault Module with 15 Switches
RAC-ACE-7 1 unit Double door storage cabinet
with tools to accommodate the
panels
RAC-ACE-8 2 units Double door storage cabinet
with tools to accommodate the
panels
6. Instruments: (RAC-ACF)
RAC-ACF-1 Volt meter Panel
RAC-ACF-2 Ammeter Panel
RAC-ACF-3 Watt meter
RAC-ACF-4 Digital Thermometer
RAC-ACF-5 Multi meter
RAC-ACF-6 Anemometer
RAC-ACF-7 Hygrometer
RAC-ACF-8 Tachometer
RAC-ACF-9 Compressor Anal


 
 

Download
» LAC-5040S
 
 

Hit Counter
Untitled Document